The power electronics training device teaching equipment has been designed to control of electrical energy with the greatest efficiency possible. In fact, the electronics training school equipment teaching equipment allows the implementation of theoretical practical courses, for the study of power electronics. The school equipment training device is also suitable for the electronics training of related majors in higher vocational colleges and secondary vocational colleges. At the same time, the electronics training device school equipment can also be used as an assessment device for power electronics training and skill appraisal in technical schools, vocational education centers, and vocational qualification appraisal stations. The power electronics training device teaching equipment school equipment could carry out different training courses with the help of training manuals and training videos.
 
Technical parameter
Dimension: About 1510mm × 610mm × 1810mm
Power supply: Three phase, AC380V/50Hz
Weigh: About 100kg
 
Product description
The Power Electronics Training device has been designed to control of electrical energy with the greatest efficiency possible. In fact, it allows the implementation of theoretical practical courses, for the study of power electronics.
Product composition
No.
Name
Specs
QTY
1
Transformer
Output: AC: 3 x 90V/1.5A with 3 center taps 45V
DC: 220V/1 A
Input: AC380V, 50Hz 3-Phase
1
2
Control unit six pulse
Single pulse or pulse train operation
Phase shift can be set for various natural commutating points: 0˚,30˚,60˚
Output: Synchronize Voltage: 1-440VAC
Control Voltage: 0-+10VDC  Input: ±15VDC
1
3
Four channels isolation amplifier
Channels can be switched on or off individually
Frequency Range: DC…80kHz
Voltage: Max 620VDC/440VAC
Overdrive indication with LEDs 4mm Safety Sockets
Input voltage: DC15V
1
4
Fault simulation phase control
A total of 20 faults from the following categories can be switched on:
Interruption/Short-circuit/Faulty assembly/Faulty components
1
5
Control unit two pulse
Single pulse or pulse train operation
Phase shift can be set for various natural commutating points: 0˚, 30˚
Output:   Synchronize Voltage: 1...250VAC
Control Voltage: 0…+10VDC
Input: ±15VDC
1
6
Thyristor with turn off circuit
Main Thyristor and Turn-off Thyristor:
Main Thyristor and Turn-off Thyristor:
VDRM: Max 800V
IT AV: Max 13A
TQ: 35µs
Free-wheeling Diode:
VRRM: Max 1000V
IT AV: Max 8A
Shunts: 4 x 0.1 ohm, 1%
Turn-off Capacitor: 4pF, 450V
Ring-around reactor: 1 m H
1
7
Control unit PWM/PFM
Operation can be selected with the following control modes: Pulse Width Modulation (PWM) and Pulse Frequency Modulation (PFM)
Control voltage: 0…+10VDC
Pulse Width Modulator:
Frequency Ranges: 20…200Hz / 0.2…2kHz/2…20kHz
Pulse Duty Factor : 0…0.95
Pulse Frequency Modulator:
Pulse Duration Ranges: 5…50µs / 50…500µs / 0.5…5ms
Frequency: 20Hz…20kHz
Output Amplifier:
Sustained short-circuit proof
Indication of switching state via 2 LEDs
INHIBIT input
Input: ±15VDC
1
8
Reference variable generator
Output: (selectable using bridging plug) 0…+10VDC
-10VDC…+10VDC
Input: ±15VDC
1
9
Trigger point limiter
LED indication for overlap
Rectifier Stability Limit: 0˚…180˚
Inverter Stability Limit: 180˚…0˚
Input: ±15VDC
1
10
IGBT
Insulated gate bipolar max 1000V
Transistor max 10A
1
11
Single phase rectifier
Periodic Repetitive Peak Reverse
Voltage: 500V
On-State Current: 10A
1
12
Fuse
Rated voltage:415VAC
Protection Fuse 2A x 3 units
1
13
Power diode
Max 1000V ;  Max 10A
1
14
Triac
Max 800V
1
15
Capacitor unit
Nominal Capacitance: 2 x 1000µF
Nominal Voltage:415V
1
16
Rectifier
Nominal Voltage: 3 x 400V
Nominal Current: 10A
Surge Forward Current: 300A
1
17
MOSFET
Max 500V; Max 10A; 0.6Ω
4
18
BULB socket
Incandescent Lamp x 3 units
Input: AC 240V, 50Hz 1-Phase
1
19
Resistor load
Resistor 100Ω x 3 units
Protection Fuse 1 A x 3 units
 
20
DC power supply
Two red LED (Voltage monitor)
4 mm Sockets
Output: 0-+15V
Input: AC 240V, 50Hz 1-Phase
1
21
Thyristor
Thyristor x 6 units
Protection Fuse 1.5A x 6 units
Max 1000V; Max 12A
1
22
AC voltmeter
Measurement Mode: AC
Voltage Ranges: 5V,50V,250V,1000V
2
23
AC ammeter
Measurement Mode: AC
Current Ranges:1 A, 5A, 25A
2
24
DC voltmeter
Measurement Mode: DC
Voltage Ranges: 5V,50V,250V,1000V
2
25
DC ammeter
Measurement Mode: DC
Current Ranges:1 A,5A, 25A
2
26
RLC load
Resistor 1KΩ
Inductor 50m H 2.5A with tap at 12.5m H
Capacitors 4/8/16µF, 450VAC
1
Training courses
1. Single-Phase Half-Wave Half Controlled Rectifier Circuit
2. Single-Phase Full-Wave Controlled Rectifier Circuit
3. Single-Phase Bridge-Type Controlled Rectifier Circuit
4. Single-Phase AC Booster Circuit
5. Three-Phase Bridge-Type Controlled Rectifier Circuit
6. Quenching Circuit Step-Down DC Chopper Module
7. MOSFET Step-Down DC Chopper Circuit
8. IGBT Step-Down DC Chopper Circuit
9. Passive Inverter Circuit
10. Fault Simulator
11. Connection Diagram

Send Message

  • You can only upload 1 attachments at most
  • Supported formats: PDF,JPG,PNG,EXCEL,WORD,STP,IGS,DWG,DXF,PDF,STEP
  • The size of the uploaded file should not exceed 10MB