Air conditioning trainer educational equipment
GTRT-CS01
Delivery:
EXW
minimum order:
1 set
Supply Ability:
30set / Month
Country of Origin:
Guangzhou, China
Stock Time:
45Day
Quantity:
GT2025073001
Air conditioning trainer Specific features
- Capability: Fault insertion and fault clearance
- Actual refrigeration unit functions: Cooling, heat, ventilation, dehumidification, temperature and wind speed selection, weather
- Included: Connection area for short circuit electrical control of an external unit, ac voltmeter, ac ammeter, thermometer, pressure gauge, pilot and led lamps, main control board
- Structure material: Anodized aluminum
- Air conditioning system: External and internal unit.
Additional features
- Power cables
- Pressure and temperature measurements taken around the refrigeration circuit.
- LCD display of all measured parameters
- Data acquisition via USB
- Color-coded cooling circuit according to international standards.
- Must include two i7 laptops or equivalent, with 16Gb RAM, 1 Tb SSD, 4 Gb graphics card, with mouse, 15 inch screen, webcam, Windows 11, with simulation software installed and actively licensed; and software license that allows the student to visualize parameters, using graphs and data
- Connection 110/120 single-phase60 Hz
- Air humidifier with float switch, blower, fill level indicator
- Sensors for temperature recording as well as combined humidity and temperature sensors
- Operation of individual components and plant groups and fault simulation via software
- Transfer surface: approx. 25,000 to 35,000cm2
- Air heater: 2000x 3,000W
- Axial blower: max. power consumption: 20W
- Max. flow rate: 700-900m3/h
- Humidifier: capacity 17 gallons/day to maintain relative humidity from 40% to 60%, automatic control. heater: 2000W-3000W
- Measuring ranges: temperature: 2x -50...75°C, 5x 0...100°C
- Rel. humidity: 40- 60%.
- Equipment manual in physical and digital form
- Manual with the steps for the development of practical exercises of the different operations of the equipment.
- Induction on the use, operation and maintenance of the equipment, provided by qualified personnel.
- A set of pressure gauges with low, high and service hoses.
- A two-stage vacuum pump with 7-12 CFM flow rate, ½ to 1HP power, 120V voltage, including ¼, 3/8 or ½ ports for standard hoses.
- Mechanical, electrical and electronic failure types.
- 2 metric ton capacity, R410A refrigerant.
- Voltage 220, amperage 8.5 to 9.8 in normal cooling mode, with maximum peaks up to 16 amps, single phase.
Send Message